<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-13 11-09-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 51 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz 5.5 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 70 kHz 15304 1,6858
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
0,6 dBr 4,82 dBr 5,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 70 kHz MIN: 12 kHz % above 76 kHz: 1,6858 Acquired: 2025/07/13 11.08.16 Total samples: 15304 Equivalent time: 0:12:45 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,9 dBr MIN: 0,6 dBr AVE: 4,82 dBr % above 12,2 dBr: 0,0 Last value: 4,4 dBr (2025/07/13 11.08.16) 10.54 10.56 10.58 11.00 11.02 11.04 11.06 11.08 0 2 4 6 Pm [dBr]